ELISA Kit for Mucin 1 (MUC1)
Product Code:
SEA413Hu
SEA413Hu
Regulatory Status:
RUO
RUO
Target Species:
Human
Human
Application:
Enzyme-Linked Immunosorbent Assay (ELISA)
Enzyme-Linked Immunosorbent Assay (ELISA)
No additional charges, what you see is what you pay! *
Code | Size | Price |
---|
SEA413Hu-24T | 24T | £179.00 |
Quantity:
SEA413Hu-48T | 48T | £291.00 |
Quantity:
SEA413Hu-96T | 96T | £403.00 |
Quantity:
SEA413Hu-96T*5 | 96T*5 | £1,706.00 |
Quantity:
SEA413Hu-96T*10 | 96T*10 | £3,196.00 |
Quantity:
Prices exclude any Taxes / VAT
Stay in control of your spending. These prices have no additional charges, not even shipping!
* Rare exceptions are clearly labelled (only 0.14% of items!).
* Rare exceptions are clearly labelled (only 0.14% of items!).
Multibuy discounts available! Contact us to find what you can save.
This product comes from: China.
Typical lead time: 14-21 working days.
Contact us for more accurate information.
Typical lead time: 14-21 working days.
Contact us for more accurate information.
- Further Information
- Documents
- References
- Show All
Further Information
Alternative Names:
CD227; EMA; H23AG; KL-6; PEM; PEMT; PUM; CA15-3; Cancer antigen 15-3; Carcinoma-associated mucin; Episialin; Peanut-reactive urinary mucin; Polymorphic epithelial mucin
Assay length:
3h
Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Detection range:
0.625-40ng/mL
Format:
48T, 96T, 96T?5, 96T?10, 96T?100
Item Name:
Mucin 1
Method:
Double-antibody Sandwich
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mucin 1 (MUC1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mucin 1 (MUC1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mucin 1 (MUC1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Research Area:
Tumor immunity;Infection immunity;Pulmonology;
Sample type:
Tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Sensitivity:
The minimum detectable dose of this kit is typically less than 0.259ng/mL
Specificity:
This assay has high sensitivity and excellent specificity for detection of Mucin 1 (MUC1).
No significant cross-reactivity or interference between Mucin 1 (MUC1) and analogues was observed.
No significant cross-reactivity or interference between Mucin 1 (MUC1) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mucin 1 (MUC1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mucin 1 (MUC1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mucin 1 (MUC1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mucin 1 (MUC1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Uniport ID:
P15941
References
http://www.ncbi.nlm.nih.gov/pubmed/20717734; http://www.ncbi.nlm.nih.gov/pubmed/26116637; www.ncbi.nlm.nih.gov/pubmed/26446295; http://www.ncbi.nlm.nih.gov/pubmed/27182834; http://www.ijcem.com/files/ijcem0020163.pdf; https://www.ncbi.nlm.nih.gov/pubmed/28107977; https://www.ncbi.nlm.nih.gov/pubmed/29156489; https://www.ncbi.nlm.nih.gov/pubmed/29156489; https://doi.org/10.1016/j.jelechem.2018.12.044; https://www.mdpi.com/2073-4409/12/9/1281;