Overview

Regulatory Status: RUO
Target Species: Rat
Application: Enzyme-Linked Immunosorbent Assay (ELISA)

Images

1 / 1

Further Information

Assay length:
2h
Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Detection range:
493.8-40,000pg/mL
Format:
48T, 96T, 96T?5, 96T?10, 96T?100
Item Name:
Nesfatin 1
Method:
Competitive Inhibition
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nesfatin 1 (NES1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nesfatin 1 (NES1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Sample type:
Serum, plasma and other biological fluids
Sensitivity:
The minimum detectable dose of this kit is typically less than 182.5pg/mL
Specificity:
This assay has high sensitivity and excellent specificity for detection of Nesfatin 1 (NES1).
No significant cross-reactivity or interference between Nesfatin 1 (NES1) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Nesfatin 1 (NES1) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Nesfatin 1 (NES1) and unlabeled Nesfatin 1 (NES1) (Standards or samples) with the pre-coated antibody specific to Nesfatin 1 (NES1). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Nesfatin 1 (NES1) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Nesfatin 1 (NES1) in the sample.
Uniport ID:
Q9JI85

References

https://ijvst.um.ac.ir/index.php/IJHPA/article/view/21156; http://www.ncbi.nlm.nih.gov/pubmed/23537082; http://www.ncbi.nlm.nih.gov/pubmed/24829503; https://www.ncbi.nlm.nih.gov/pubmed/29604590;