ELISA Kit for Apolipoprotein A1 (APOA1)

Cloud-Clone Corp.
Product Code: CEA519Rb
Product Group: ELISA Kits
CodeSizePrice
CEA519Rb-24T24T£192.00
Quantity:
CEA519Rb-48T48T£314.00
Quantity:
CEA519Rb-96T96T£435.00
Quantity:
CEA519Rb-96T*596T*5£1,850.00
Quantity:
CEA519Rb-96T*1096T*10£3,467.00
Quantity:
Prices exclude any Taxes / VAT

Overview

Regulatory Status: RUO
Target Species: Rabbit
Application: Enzyme-Linked Immunosorbent Assay (ELISA)

Images

1 / 1

Further Information

Alternative Names:
Apo-A1; ApoA-1 Milano; ProapoA-I; Proapolipoprotein A-I; Truncated apolipoprotein A-I
Assay length:
2h
Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 5 times;
4. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
5. Add 50µL Stop Solution. Read at 450 nm immediately.
Detection range:
24.69-2000ng/mL
Format:
48T, 96T, 96T?5, 96T?10, 96T?100
Item Name:
Apolipoprotein A1
Method:
Competitive Inhibition
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Apolipoprotein A1 (APOA1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Apolipoprotein A1 (APOA1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Research Area:
Metabolic pathway;Cardiovascular biology;Hepatology;
Sample type:
Serum, plasma and other biological fluids.
Sensitivity:
The minimum detectable dose of this kit is typically less than 10.62ng/mL
Specificity:
This assay has high sensitivity and excellent specificity for detection of Apolipoprotein A1 (APOA1).
No significant cross-reactivity or interference between Apolipoprotein A1 (APOA1) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test Principle:
The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Apolipoprotein A1 (APOA1) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ? 10nm. The concentration of Apolipoprotein A1 (APOA1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Uniport ID:
P09809