CLIA Kit for Indole 3 Acetic Acid (IAA)

Cloud-Clone Corp.
Product Code: CCA737Ge
Product Group: CLIA Kits
CodeSizePrice
CCA737Ge-24T24T£247.00
Quantity:
CCA737Ge-48T48T£410.00
Quantity:
CCA737Ge-96T96T£573.00
Quantity:
CCA737Ge-96T*596T*5£2,472.00
Quantity:
CCA737Ge-96T*1096T*10£4,643.00
Quantity:
Prices exclude any Taxes / VAT

Overview

Regulatory Status: RUO
Target Species: Species Independent
Application: Chemiluminescent Immunoassay (CLIA)

Images

1 / 1

Further Information

Alternative Names:
IA-A; Indolylacetic Acid; Indoleacetic Acid; Heteroauxin
Assay length:
2h
Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
Detection range:
1.56-400ng/mL
Format:
48T, 96T, 96T?5, 96T?10, 96T?100
Item Name:
Indole 3 Acetic Acid
Method:
Competitive Inhibition
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Indole 3 Acetic Acid (IAA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Indole 3 Acetic Acid (IAA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Research Area:
Signal transduction;Hormone metabolism;
Sample type:
Tissue or cell culture supernates
Sensitivity:
The minimum detectable dose of this kit is typically less than 0.63ng/mL
Specificity:
This assay has high sensitivity and excellent specificity for detection of Indole 3 Acetic Acid (IAA).
No significant cross-reactivity or interference between Indole 3 Acetic Acid (IAA) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test Principle:
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Indole 3 Acetic Acid (IAA). A competitive inhibition reaction is launched between biotin labeled Indole 3 Acetic Acid (IAA) and unlabeled Indole 3 Acetic Acid (IAA) (Standards or samples) with the pre-coated antibody specific to Indole 3 Acetic Acid (IAA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Indole 3 Acetic Acid (IAA) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Indole 3 Acetic Acid (IAA) level in the sample or standard.