Mini Samples ELISA Kit for Stem Cell Factor (SCF)

Cloud-Clone Corp.
Product Code: MEA120Mu
Product Group: ELISA Kits
CodeSizePrice
MEA120Mu-24T24T£189.00
Quantity:
MEA120Mu-48T48T£309.00
Quantity:
MEA120Mu-96T96T£428.00
Quantity:
MEA120Mu-96T*596T*5£1,820.00
Quantity:
MEA120Mu-96T*1096T*10£3,411.00
Quantity:
Prices exclude any Taxes / VAT

Overview

Regulatory Status: RUO
Target Species: Mouse
Application: Enzyme-Linked Immunosorbent Assay (ELISA)

Further Information

Alternative Names:
KITLG; MGF; SF; KL1; Kitl; FPH2; Kit-Ligand; Steel Factor; Mast Cell Growth Factor; Steel factor; Familial Progressive Hyperpigmentation 2
Assay length:
3h
Assay Procedure Summary:
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.
Detection Range:
15.6-1,000pg/mL
Format:
48T, 96T, 96T?5, 96T?10, 96T?100
Item Name:
Stem Cell Factor
Method:
Double-antibody Sandwich
Precision:
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Stem Cell Factor (SCF) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Stem Cell Factor (SCF) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Research Area:
Cytokine;Hematology;
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Sensitivity:
The minimum detectable dose of this kit is typically less than
Specificity:
This assay has high sensitivity and excellent specificity for detection of Mini Samples Stem Cell Factor (SCF).
No significant cross-reactivity or interference between Mini Samples Stem Cell Factor (SCF) and analogues was observed.
Stability:
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Stem Cell Factor (SCF). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Stem Cell Factor (SCF). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Stem Cell Factor (SCF), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples Stem Cell Factor (SCF) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Uniport ID:
P20826

References

https://www.ncbi.nlm.nih.gov/pubmed/30974849;